NRO Connection Configuration Instructions


  1. Navigate to C:\Program Files (x86)\Radiant Systems\Integration Agent\Bin\NROIntegration and click on NROConnectionConfig.exe .
  2. The NRO Connection Config window appears. Enter the Website URL , User ID , and Password then select Test Connection .
  3. TIP: The Test Connection button is disabled until these three pieces of data are entered .



    If the connection is SUCCESSFUL, this window appears.



    If the connection is UNSUCCESSFUL, this window appears. Contact Support for assistance.



  4. Next, enter the Guest Customer Number.  T his is the customer number used as the Template Customer under Setup / Ecommerce / Control / Customers in Counterpoint.  Note that this Customer record must contain something in the First Name, Last Name, Street Address, City, State, Zip Code, Country, Phone 1, and Email 1 fields (it does not have to be a valid email address, but it must be properly formatted - xxx@ncrretailonline.com).  This Customer record must also be marked as an Ecommerce customer, and must be published to NRO.  See http://help.ncrretailonline.com/article/publishing-your-counterpoint-customers-to-ncr-retail-online.html for information about publishing customers.
  5. Enter the Data , Product Media and Category Media Paths and select Save when complete.
  6. Choose Save when complete and select OK on the following screen. Last, click on the X in the right hand corner to close the NROConnectionConfig utility.



TIP:  If you receive the following error message: "There was an error saving the Companies.xml file.  Please check the log for details," you will need to run the NROConnectionConfig.exe as administrator by right-clicking the filename (in Windows Explorer) and left-clicking "Run as administrator."  This is sometimes necessary even when logged in to the machine as Administrator.

run as administrator



Article ID: 323
Created On: Wed, Sep 19, 2012 at 7:33 PM
Last Updated On: Wed, Apr 20, 2016 at 12:58 PM

Online URL: http://help.ncrretailonline.com/article/nro-connection-configuration-instructions.html